EM_WRSM_NL_003

Objective

Summary No load FEMM versus hybrid permeance/mmf model
Topology WRSM
Models Hybrid Permeance/mmf electromagnetic model
Outputs Radial airgap flux density
Geometry Salient pole synchronous machine
Winding Distributed winding

Machine

MANATEE model for WRSM_001
MANATEE model for WRSM_001

Results

Radial airgap flux (Femm vs Permeance/mmf)
Radial airgap flux (Femm vs Permeance/mmf)

One can see that the radial flux density is better calculated using this hybrid permeance/mmf model compared to EM_WRSM_NL_002 (calculation of mmf with FEMM but not stator permeance) and EM_WRSM_NL_004 case (no coupling with FEMM at load). The mmf calculation and the permeance calculations are here more accurate using automated coupling with FEMM.

Application to e-NVH

MANATEE software can quickly calculate electromagnetic noise and vibrations of wound rotor synchronous machines using this type of fast electromagnetic models.