Objective
Topology | SCIM |
---|---|
Model Types | |
Quantities | Sound power level |
Geometry | Internal rotor Semi-closed slots |
Winding | Overlapping distributed winding |
This article aims at validating the use of symmetries (Input.Simu.is_symmetry=1) in MANATEE on a squirrel cage induction machine at no load.
Machine
SCIM_018 topology is confidential.
Results
One can see that the automated identification of time & space symmetries works correctly as same results are obtained without symmetries. The use of symmetries significantly reduces the computing time of MANATEE.